Wangtong M-1610-00SF fingerprint cam lock ยท every locker at 1660 9th St ยท from the manufacturer's own manual โ nothing invented
โก The USB port = emergency power. Nothing else.
Dead battery? Hold a USB power bank cable to the port โ lock wakes up โ scan enrolled finger โ open. It transfers no data.
๐ท๏ธ Model M-1610-00SF
๐ญ Ningbo Wangtong Locks
๐ Battery CR2450 ยท ~1 yr
๐ 2 admin + 8 user prints per lock
โ ๏ธ Fresh / factory-reset lock = ANY finger opens it. The fingerprint database starts empty. First finger enrolled becomes the ADMIN print โ enroll a manager immediately.
๐ฆ Something's wrong โ start here
Symptom
Meaning
Fix
โ Totally dead, no light/beep
Battery empty
USB power bank to port โ open โ replace CR2450 (or swap battery from the front โ see below)
โ 3 short beeps (di-di-di)
Finger not enrolled / not recognized
Use the ADMIN finger. Reposition finger, press flat, retry
! Red light on
Low battery warning
Replace CR2450 now โ it may stop working soon
โ Long beep + light
Accepted
Turn the knob within 3 seconds or it re-locks
โ Locked & nobody's finger works
Unknown prints enrolled
No front-side override exists. Power via USB + try all managers. Last resort: contact Jason (below) or drill the cam
๐ Daily use
๐ Open a locker
1Hold enrolled finger on reader ~1 sec โ long beep + light
2Turn the knob within 3 sec โ open
๐ Lock it
1Close door, rotate knob back โ locked
๐ Replace battery (door can stay shut)
1Push pin into the emergency hole on the front face
2Rotate the round cover
3Pull cover off โ swap CR2450 coin cell in battery box
๐ ๏ธ Enroll & reset fingerprints
โญ Set the ADMIN fingerprint
Way A (empty lock): finger 1s โ long beep, green on โ same finger 3s โ 2 short beeps, green flash โ ready
Way B: press RST button (back of lock, inside door) โ long beep, green flash โ ready
Then press admin finger 3ร โ short beep each = good; long beep = admin saved
3 short beeps = failed โ shift finger position, retry
โ Add a member's finger (max 8)
1Admin finger 1s โ long beep, green on
2Admin finger again 1s โ 2 short beeps, green flash
3Member presses finger 3ร โ long beep = saved
๐๏ธ Wipe MEMBER prints (keep admin)
1Admin finger โ long beep, light on
2Admin again โ 2 short beeps, light flash
3Admin a 3rd time โ long beep = all user prints gone
๐งจ Wipe EVERYTHING (incl. admin)
1Do the 3-touch wipe at left
2Then hold admin finger 3 sec โ every print deleted
3Lock is now factory-empty โ any finger opens โ re-enroll admin
๐ Hardware reset (door open)
Push pin into the hole on the back side of the lock
Short beep = lock reset, without unlocking
๐ Private โ Public mode
Remove battery โ hold pin in the reset hole โ re-insert battery while holding
Release at 1 long beep = private mode
Release at 3 long beeps = public mode
Admin finger opens in both modes. (Manual doesn't define the modes further)